Scoop buying guide

How to read a food-contact test report for scoops and cutlery

Short answer

A food-contact test report records the results for one submitted sample: which tests were run, which methods or standards were cited, at what conditions, and against which limits. To use a report for your order, check five things in this order: the sample, the standards and their editions, the test conditions, each result against its limit, and the date and laboratory.

Becutlery Published

How to use this guide

This guide uses the actual pages and numbers of our 13 published product test reports to show what the tests measure and where a report is most often misread.

What the tests in our reports measure

This table describes the tests in our reports, not the full scope of each law.

What the tests in our reports measure
Test on the reportWhat it coversWhat the laboratory measuredIn our reports
FDA 21 CFR 175.300Resinous and polymeric coatingsChloroform-soluble extractives, in mg per square inchBS2554 green scoop: not detected, below the 0.5 mg/in² reporting limit
Chromium content ("US FDA GRAS" on the report)The steelTotal chromium, in %BS2554: 16.43%; BS2532: 16.45%
CM/Res(2013)9 or CM/Res(2020)9Metals and alloysRelease of 21 to 24 metals into a test liquid, in mg/kgBS2554, BS2558 and BS2529: pass
(EC) 1935/2004Food-contact materials and articles within its scopeNo single test: it sets general safety requirements, and reports cite it with specific testsCited in five of our reports, with CM/Res or (EU) 10/2011
LFGB §30–31 with (EU) 10/2011The PP part in our BS4013 reportOverall migration into a test liquid, in mg/dm²4.0, 3.7 and not detected, against a limit of 10
Bisphenol A (BPA)The PP part in our BS4013 reportBPA in the material, in mg/kgNot detected, below 0.1 mg/kg
Lead and cadmium content, to client limits referring to California Proposition 65The steel of a stainless steel spoonTotal lead and cadmium in the material, in mg/kgBoth not detected, below 10 mg/kg; client limits 100 and 300 mg/kg

Two practical points follow. A coated scoop has the coating as its food-contact surface, so ask for tests that cover the coating as well as the base metal. And plastic parts are tested with plastics methods: in our BS4013 children's cutlery report, the steel and the PP handle were tested separately, with different tests for each.

Check 1: Is the report about your product?

The first page names the sample, model number and material, and the wording matters. Our reports introduce the sample as "the submitted samples said to be" and mark the material as "claimed by client". The statement page says the laboratory is not responsible for the authenticity of the information the applicant provides, such as the sample name, material or model number. The material description supplied by the applicant is not itself a test result. Read the actual tests and acceptance criteria before treating a report as evidence of a particular steel grade.

Then compare the sample with what you are buying:

  • Model: the same shape and size, not just the same product type.
  • Base material: a 430 stainless steel result does not stand in for 304, or the reverse.
  • Surface: a polished scoop and the same scoop with a coating or plating have different food-contact surfaces.
  • Food-contact parts: make sure every part that touches food is covered by a suitable test.

Our BACL reports state that their results refer only to the samples tested. A report on one model is not a certificate for a whole range.

Check 2: Which standards, and which editions?

Standards are revised, and a report is judged against the edition the laboratory used. In 2024 the European Directorate for the Quality of Medicines & HealthCare (EDQM), part of the Council of Europe, published the second edition of its technical guide on metals and alloys, which builds on Resolution CM/Res(2020)9. Our own reports show how the limits changed:

Check 2: Which standards, and which editions?
MetalLimit in our reports under CM/Res(2013)9 (2021 and June 2024)Limit in our report under CM/Res(2020)9 (September 2024)
Chromium0.25 mg/kg1 mg/kg
Manganese1.8 mg/kg0.55 mg/kg
Thallium0.0001 mg/kg0.001 mg/kg
Zirconiumnot tested2 mg/kg
Nickel0.14 mg/kg0.14 mg/kg
Lead0.01 mg/kg0.01 mg/kg

These are the limits printed in our reports. In the EDQM second edition, the 1 mg/kg chromium limit applies to chromium(III); chromium(VI) is dealt with separately. The guide also contains provisions for specific uses, so "passed CM/Res" is not a complete statement: ask which resolution and which edition of the guide a report uses, and which provisions apply to your product.

The US rule for coatings distinguishes four cases. Under 21 CFR 175.300(c), the area-based limit is 0.5 mg/in² for a single-use container with a capacity of 1 gallon or less, 1.8 mg/in² for a larger single-use container, and 18 mg/in² for a repeated-use container or a repeated-use coating on an article other than a container. Container coatings must also meet the water-capacity restriction in paragraphs (c)(1)–(3): 0.005% of the container’s water capacity, in milligrams, divided by its food-contact area, in square inches. Our BS2554 report used 18 mg/in²; both reported results were below its 0.5 mg/in² reporting limit. Ask the laboratory to confirm the applicable category and conditions for your article.

The chromium check is a third example. Two of our reports from the same laboratory state different requirements for the same test: at least 10.5% chromium (June 2024) and at least 16% (December 2024). 10.5% comes from the European definition of stainless steel, which is at least 10.5% chromium and no more than 1.2% carbon (EN 10020). Meeting it does not verify a particular steel grade. If your retailer or market expects a particular threshold, agree it before the sample goes to the laboratory.

Check 3: Do the test conditions match how the product is used?

Migration tests expose the item to a test liquid, called a simulant, at a set temperature for a set time. Our reports used these conditions:

  • Metals, BS2529 and BS4013 (2021): 0.5% citric acid at 40 °C for 30 minutes
  • Metals, BS8038 butter knife (2021): 0.5% citric acid at 40 °C for 1 hour
  • Metals, BS2554 and BS2558 (2024): artificial tap water at 40 °C for 1 hour
  • Overall migration, BS4013 PP part (2021): 10% ethanol at 40 °C for 30 minutes
  • Coating test, BS2554 (2024): distilled water at 150 °F (about 66 °C) for 2 hours, and n-heptane at 100 °F (about 38 °C) for 30 minutes

The conditions should represent the intended and reasonably foreseeable use. For metals, the EDQM guide refers to the EU Joint Research Centre's kitchenware guidelines for test contact conditions. When you ask for testing, describe the real use: dry powder, coffee grounds, acidic drinks, hot liquids or dishwasher cleaning. A report run at milder conditions than your use does not answer your question.

Check 4: Read each result against its limit

"N.D." means not detected, not zero. The amount was below the reporting limit (RL) or method detection limit (MDL) printed next to the result.

Check that the method is sensitive enough for the limit. Divide the reporting limit by the limit:

  • Lead in our BS2554 report: 0.005 ÷ 0.01 = 0.5. "N.D." shows lead was under half the limit.
  • Nickel: 0.002 ÷ 0.14 ≈ 0.014, so under about 1.4% of the limit.
  • Thallium: 0.0001 ÷ 0.0001 = 1. The reporting limit equals the limit, and the laboratory judged "N.D." as a pass.

If the reporting limit is above the limit, an "N.D." result alone cannot show that the amount is below the limit. When the two are equal, or a result is close to the limit, ask the laboratory how it defines N.D. and which decision rule it applies. Our BACL reports state that, unless the applicant or product regulations require otherwise, their decisions do not take measurement uncertainty into account.

A pass is not always "N.D." In our BS4013 report, iron was measured at 0.86 mg/kg in the third exposure, against a limit of 40 mg/kg. Read every number against its limit.

Repeated-use items are tested more than once on the same piece. In our metal reports, the item goes through three exposures. The report adds the first two results and compares the total with 7 times the limit, then compares the third result with the limit itself. For the PP handle in our BS4013 report, overall migration was measured three times: 4.0, 3.7 and not detected (below 3) mg/dm², against a limit of 10 mg/dm². The report marks the series as stable; the values fell from one test to the next.

Check the unit. Metal results are in mg/kg: milligrams released per kilogram of food. Plastic results are often in mg/dm²: milligrams per square decimetre of surface. The BS2554 and BS2558 reports use a surface-area-to-volume ratio of 6.0 dm²/kg. At that ratio, 10 mg/dm² corresponds to 60 mg/kg (10 × 6). Article 12 of Regulation (EU) No 10/2011 sets a general overall migration limit of 10 mg/dm², and a separate 60 mg/kg limit for plastics intended for food for infants and young children. Use the limit and conversion that apply to your article.

Content is not migration. Our Proposition 65 report measured the total lead and cadmium in the steel, in mg/kg of material, not what moves into food. It compared them with limits the client specified, 100 mg/kg for lead and 300 mg/kg for cadmium, and the conclusion reads "meet the requirement of client". Those are the report's acceptance criteria, not Proposition 65 safe harbor levels, which are set as daily exposure: for lead, 0.5 micrograms per day for reproductive toxicity. Passing a content test alone does not settle whether a warning is required for the product's actual use. Ask your retailer which limits they use.

Check 5: Date, laboratory and the full copy

  • Dates: the report date and the testing period are on page 1. Our published reports run from 2019 to 2026.
  • Laboratory: the name and address are printed on every page.
  • Full copy: our BACL reports state that they may not be reproduced except in full without the laboratory's prior written approval, and that they are valid only with a valid digital signature. Ask for the complete PDF, not a summary page, and read the statement page, which also sets out how the results may be used.
  • Changes: the laboratory keeps tested samples for 30 days. A change of material, finish, color, components or requirements should prompt a review of whether the existing report still represents your product and whether more testing is needed. Retailers and platforms set their own rules for how recent a report must be; ask yours.

Factory records are not product tests

A factory audit or supplier verification describes the facility, not a product. A product test report describes one sample. Our amfori BSCI monitoring summary (Bureau Veritas) and our TÜV Rheinland on-site verification (report 486336643_P+T) are factory records. The 13 published laboratory reports discussed here are product tests. A buyer may need both, for different purposes.

Our measuring scoop reports

Our measuring scoop reports
ModelCapacitySizeWeightMaterial and surface on the reportReport
BS253210 ml (0.68 US tbsp)128 × 40 × 15 mm21 gStainless steel, dark grey plating2406Z30254A: chromium content
BS252920 ml (1.35 US tbsp)154 × 49 × 15 mm35 g430 stainless steelXMTN2210611-22733E: CM/Res(2013)9
BS255420 ml (1.35 US tbsp)126 × 40 × 25 mm37 g304 stainless steel, green surface2406T33755A: FDA 21 CFR 175.300, chromium content, CM/Res(2013)9
BS255850 ml (3.38 US tbsp)156 × 50 × 28 mm50 gStainless steel, black coating2406X55599E: CM/Res(2020)9

The material column repeats what each report records for its sample. Our other nine product reports cover a butter knife, a cutlery set, a children’s cutlery set, a manual whisk, two stainless steel spoons, a BPA test on a tableware set, a wheat-straw bowl tested to GB 4806.7-2023 for China, and a 50 ml silver-coloured stainless-steel scoop. All 13 are on our certificates page, each with the original PDF. The 50 ml sample is covered by report 2606X21511E; its report does not identify a Becutlery model number.

Arranging testing for your order

We work with partner test laboratories, including BACL and TÜV Rheinland, and can arrange testing for any of our products: US FDA, LFGB and (EC) 1935/2004, California Proposition 65, or the standard your market or retailer names. See lab testing for your order.

  1. Tell us the market and the checklist. Name the destination country and any retailer or platform requirements.
  2. Describe the exact item. Model, steel grade, finish or coating color, logo method and any plastic parts.
  3. Agree the test items and limits. We confirm them with the laboratory, so that every food-contact material and surface is covered.
  4. Send the sample to the laboratory. Four earlier scoop reports record 3–7 calendar days from sample receipt to the report date: 2406T33755A, 2406X55599E, 2406Z30254A and XMTN2210611-22733E. The later report 2606X21511E records receipt on 10 September 2026 and a report date of 28 October 2026, an interval of 48 calendar days; its testing period is separately recorded as 10 September to 9 October. These are historical receipt-to-report intervals, not continuous testing durations or guaranteed turnaround times. Confirm the schedule with the laboratory and allow for shipping, additional tests and retests. See our production timeline guide.
  5. Receive the full report. You get the complete PDF.

Prefer your own inspection company or laboratory? You may appoint one at your own cost. Ask us for a testing quote with your order.

For brands

Plan the test list once for every market you sell in: a coated scoop sold in the US and the EU may need tests covering both the coating and the metal, each to the edition that applies. Fix the finish, color and logo method before testing, since a later change means reviewing whether new tests are needed. If the scoop is packed inside a tub or pouch with your product, tell us, so the conditions reflect real contact. See stainless steel grades and finish options.

Stock models start from 100 pieces. Regular sample preparation takes 10 days, and we reply within 24 hours. Logo samples are charged; the Logo sample fee is refunded when you place a bulk order, while shipping costs are not refundable. Request a quote

FAQ

What does N.D. mean on a test report?

N.D. means not detected under the reporting or detection limit stated in the report. It does not mean zero. Read the result together with that limit and the acceptance criterion.

What does LFGB mean?

LFGB is Germany's Food, Articles of Daily Use and Feed Code, and it is not limited to plastics. For food-contact articles, §31 refers to the general safety requirements in Article 3 of Regulation (EC) No 1935/2004. A US test report does not automatically show compliance with German or EU requirements.

What does FDA compliance mean?

It means meeting the US FDA requirements that apply to the article. For food-contact coatings, one of these is 21 CFR 175.300; our BS2554 report records testing of the submitted green scoop under that rule at the stated conditions. The result applies to that sample and test, not to every model or finish.

What is California Prop 65?

Proposition 65 is a California law about exposure to chemicals on its list, such as lead; it is not a product certification. Whether a warning is required depends on exposure and on any exemption that applies. A laboratory content test against a client's limits, such as ours, does not by itself answer that question.

Related guides: Plastic vs stainless steel supplement scoops · How to prepare a cutlery RFQ · Measuring scoop capacity guide